Inspection Date 7/2/2025
Final Score @ Grade
26
General CommentsInspection conducted with CPO Yovanny Geronimo Verified items from 6/23/2025 inspection and conducted pre-permit inspection. - When pool steps were replastered, last step was made into a slope. Slope is 3:8 rise to run on one end, 4:14 on the other end before slope gets less steep and merges with pool floor. When pool is replastered next, will need to make step area complaint with section .2516 of the pool rules. - Pump set at 2600 RPM. No pump curve for 2600 RPM. - Permit condition that flow is required at 106 to 146 GPM to meet turnover and flow restriction of the filters. Will need to keep operable pressure gauges in place to measure flow and keep pump set at a speed for which there is a pump curve. - Operator adjusted to 3110 RPM. (2.31x21psi) + (1.13x6.5 in Hg) = 55.86 TDH = 127 GPM on pump curve. Immediate suspension still in place 3) Re-inspection fee paid. Re-inspection scheduled for tomorrow at 9:30 AM.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. Operator added additional chemicals, unable to raise pH. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one weir. .2518(k) Provide functional weirs. - CPO has weirs on order.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed new US Coast Guard approved ring buoy, throw rope too long. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inches in diameter. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No FlowVis flow meter only reads up to 110 GPM. .2518(g) Install flow meter on return line per manufacturer instructions that is capable of reading between minimum turnover and the maximum velocity of the piping. - Will give facility 30 days to make corrections.
27 2 Equipment room: filter backwash discharged through an air gap No No No One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restrooms renovated. Provided documentation that mirrors are shatterproof. .2526(k) Provide shatterproof mirrors. - Will give facility 30 days to make correction.