| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH < 6.8. Operator added additional chemicals, unable to raise pH. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Missing one weir. .2518(k) Provide functional weirs. - CPO has weirs on order. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed new US Coast Guard approved ring buoy, throw rope too long. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inches in diameter. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
FlowVis flow meter only reads up to 110 GPM. .2518(g) Install flow meter on return line per manufacturer instructions that is capable of reading between minimum turnover and the maximum velocity of the piping. - Will give facility 30 days to make corrections. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Restrooms renovated. Provided documentation that mirrors are shatterproof. .2526(k) Provide shatterproof mirrors. - Will give facility 30 days to make correction. |
|