NameONE NORMAN SQUARE APARTMENTS
Address19532 ONE NORMAN BOULEVARD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/3/2024
Final Score @ Grade
8
General CommentsInspection conducted with CPO Ricardo Trujillo. - CPO has been using Calcium Hypochlorite tablets in erosion chlorine feeder designed for Triclor, which has spilled a slurry of chemical over pump room floor.. Chlorine feeder is not approved for use with this product. - Ensure only using approved products with NSF approved chlorinator. Clean up spilled chemicals in pump room. - *NOTE* Mixing Triclor and Calcium Hypochorite can cause an explosive reaction. - Facility has pump locked at 2600 RPM. - Will need to maintain pump locked at 3110 RPM or less at a flow between what is needed for minimum turnover and 146 GPM, which is the max the filters can handle. - No pump curve for 2600 RPM. Not able to determine flow on today’s visit using pressure and vacuum gauges. - When steps were replastered, last step was made into a slope. Slope is 3:8 rise to run on one end, 4:14 on the other end before slope gets less steep and merges with pool floor. When pool is replastered next, will need to make step area complaint with section .2516 of the pool rules. - Back gate opens towards pool due to topography. If gate is ever replaced will need to meet requirements in .2528. - Main drain covers expire 5-11-2025. Replace with new ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to our office for approval prior to drain cover expiration.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder loose. .2521 Install ladders per manufacturer instructions. Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.