Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameONE NORMAN SQUARE APARTMENTS
Address19532 ONE NORMAN BOULEVARD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/3/2024
Final Score @ Grade
20
General CommentsInspection conducted with CPO Joshua Gonzalez. - Facility has pump locked at 2350 RPM. (10 PSI x 2.31) + (6.3 Hg x 1.13) = TDH of 30 at 2350 RPM. ~ 103 GPM per pump curve. - Will need to maintain pump locked at 3110 RPM or less at a flow between what is needed for minimum turnover and 146 GPM, which is the max the filters can handle. Observed new FlowVis flow meter reading ~105 GPM. Max it can read is 110 GPM. - When steps were replastered, last step was made into a slope. Slope is 3:8 rise to run on one end, 4:14 on the other end before slope gets less steep and merges with pool floor. When pool is replastered next, will need to make step area complaint with section .2516 of the pool rules. - Main drain covers expire 5-11-2025. Replace with new ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to our office for approval prior to drain cover expiration. Intent to suspend issued 16) Current permit expires 4-30-2024. Will need to correct ITS items prior to permit expiration.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder loose. .2521 Install ladders per manufacturer instructions. Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing at pool steps. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope tangled and tied through multiple beckets on ring buoy. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Back gate not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected. Section of fence missing at retaining wall. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier with no gaps > 4” through the fence, no gaps > 2” under the fence, and at least 45” between horizontals. - Intent to suspend item.
18 4 Premises: lifeguards present or warning signs posted No No No Safety signage not visible from back entrance to pool. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected. Sign on main gate moved to inside pool area. Safety signage not visible from back entrance to pool. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected. Sign on main gate moved to inside pool area.