General CommentsConducted pre-permit inspection with CPO Josh Gonzalez. Most issues from previous inspection have been addressed. Verified PDSC information. Facility has pump locked at 2350 RPM. TDH calculation after a backwash of 27.85, or 110 GPM. Will need to maintain pump locked at 3110 RPM or less at a flow between what is needed for minimum turnover and 146 GPM, which is the max the filters can handle. Pre-permit inspection did not pass 16) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder loose. .2521 Install ladders per manufacturer instructions. Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed new US Coast Guard approved ring buoy with new throw rope > 50 feet long. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected to 50 feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Main gate < 48” high. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. - Pre-permit item. Back gate opens inward due to topography. Gap under gate > 4”. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). - Pre-permit item. Magna-Latch < 54” high. .2528(a) Gate latches shall be 54" in height. - Pre-permit item.
27 2 Equipment room: filter backwash discharged through an air gap No No No One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Out of toilet paper in men’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms. - Corrected.