| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Spotty record keeping. No place for total alkalinity checks. Drain checks appear to be more that water is clear enough to see drains than that drain covers are secure and in good condition. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
No flow in far skimmer. .2518(k) The flow-through rate through anyone recessed skimmer shall be between 20 GPM and the maximum flow the skimmer is certified for under NSF 50. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Ladder loose. .2521 Install ladders per manufacturer instructions.
Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color bands do not extend all the way to the pool wall. .2521(b) Tile shall be no more than one inch from the edge of the tread or adjacent tiles. - Ensure this is addressed the next time the pool is replastered. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some deck chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
WARNING - NO LIFEGUARD ON DUTY signs in 2 1/2” lettering. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not able to reach Kings III. When I call the box, I get a number not in service message. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
Emergency phone located outside the pool enclosure. Not easily visible from all parts of the pool. .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. - Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed 2” Blue-White Flow Meter installed on 2 1/2” return line. .2518(g) Install flow meter on return line per manufacturer instructions. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Lots of items cluttered on chemical storage room floor, not easily accessible. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Leak at chlorinator. .2533(d) Pump room floor shall be kept dry and free of standing water.
Some items stored next to equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Some bags of dry chemicals stored on the ground. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Most piping appears to be new, not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower handle broken, shower not longer operable. .2526(h) Shower(s) shall be provided. |