Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLANTOWER GARRISON PARK
Address3450 WILBURY CIR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2022
Final Score @ Grade
10
General CommentsNOTE: INSPECTION CONDUCTED 4/13/22 WHILE FACILITY STILL PERMITTTED AS 530491. GC: Inspection conducted with Rob Bromstrup. Rob is the new CPO. Updated CPO information. Wingnuts for body hook screws face inside towards the hook. Recommend having nuts face away from hook to prevent injury when being used. Posted pool hours are 10 AM - 10 PM. Pool not permitted for night swimming. Recommend changing to reflect that pool closes at dusk or call to schedule a pool night lighting inspection. Have not yet received application and payment for the coming pool season. Please call our office (980-314-1620).

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on pool log sheet for main drain, total alkalinity or cyanuric acid checks. .2535( 11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Operator will start using state log sheet.
18 4 Premises: lifeguards present or warning signs posted No No No WARNING - NO LIFEGUARD ON DUTY sign in less than 4" lettering. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in the chemical storage room not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.