NameMAGNOLIA HEIGHTS
Address3620 STERLING MAGNOLIA CT
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2026
Final Score @ Grade
32
General CommentsPump housing and lid replaced and not able to be verified as correct pump. Motor has been replaced, 5 HP. There are no notes indicating these changes have been approved or documented with the health department. Unable to verify timeline or permits at time of inspection. Submit documentation for PDSC to pdsc@mecknc.gov Ensure proper electrical permits have been pulled for motor replacement. Re-inspection fee required. Call Main Office at 980-314-1620 once ALL 4 and 6 point demerits are corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8 at beginning of inspection. CPO attempted to raise pH. EHS observed pH at 6.8 at end of inspection. Permit denied
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed record papers not including the main drain checks. CPO added main drain checks to record papers.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. PDSC form indicates Pentair Challenger CFII-N15FE. Pump housing and lid has been changed and unable to verify pump. Housing does not appear to be NSF certified. Pump basket lid with rusted ring does not appear to meet NSF approval. Provide proper documentation for PDSC form and pump. Permit denied
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed missing rubber cap on ladder.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed body hook on a telescoping pole. CPO switched body hook to a non-telescoping pole.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed lounge chairs within 6 feet of waters edge. Permit denied
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed “No life guard on duty” section of signage at less than 4 inches. CPO purchased new signage with 4 inch lettering