2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm.
Chlorine recorded at .1. CDI - Automatic dispenser turned on and by end of inspection chlorine recorded 2.0 ppm. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
Vaccum outlet was not secured. CDI = Secured |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Rope was too long (60 feet). CDI - Cut to appropriate length (50 feet)
.
2530(a) Provide at least 12 ft. long pole with body hook securely attached.
Body hook was not securely attached. CDI - Securely attached with screws. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Chairs and lawn chars obstructed 6 feet of clearance. CDI - Chairs moved. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Incorrect phone number and address posted. 9-1-1 had different info. CDI - Changed address and phone number to what was on 9-1-1’s record. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels.
Pipes not labeled. Label pipes |