10
|
0
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf
Observed no paper towels at the front hand sink upon arrival. -CDI- PIC immediately provided a stack of paper towels for the hand sink. (0 pts) |
|
41
|
0.50
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses.
Observed wiping cloths being stored in quat concentration of less than 50ppm. -CDI- PIC replaced the sanitizer solution with new solution of 200ppm. (0.5 pts) |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair.
Observed torn gasket on WIF. Replace gasket. REPEAT*** (0.5 pts) |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues.