5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records on weekends. If pool is closed, mark closed in log book. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2537(7) Drain covers shall be in good condition and securely attached. Observed damage to drain cover surface ridges on both covers where some are broken off. Covers are 2008 AQUASTAR WAVRWR101 expiring 1/17/2027. They must be replaced with appropriate new covers that will handle the flow rate of the system and new PDSC paperwork must be submitted and approved by the Health Department main office. Contact C. Elmore (704-507-6814) when covers are replaced and the PDSC paperwork is approved by the Health Department main office. (Main office 980-314-1620). |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed 1 weir missing out of 4 total skimmers. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed throw rope to be too long. Rope was corrected to the 47 fool length required for this pool. |