2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
0.2 ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records last two weekends. If pool is closed, mark in log book. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Permit condition that feature pump must be at 60 GPM or less due to restriction on main drains. Observed at 72 GPM. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. - Immediate suspension item. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Erosion chlorinator not working. No flow in flow meter for chlorinator. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap. |