Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBROOK APARTMENTS, THE
Address9924 OAKBROOK DR
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/7/2022
Final Score @ Grade
48
General CommentsImmediate suspension for water clarity, water quality, buoy rope. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept., Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Update property management changes. Other permit items: records, CPO certification, gate latching, flow meter, 6’ clearance and skimmers. Contrasting color bands must be corrected for 2023 permit. Skimmer equalizer covers (3 6HP) expire 09/23. Replace or plug and update PDSC form prior to expiration.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Water too cloudy to see main drains. .2535(2) Main drains must be clearly visible from the pool deck. *Immediate suspension item
3 6 Water quality: pool water pH No No No PH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records being kept and no certification for new pool operator. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. *Permit items
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. *Permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder on left side of pool 10” from wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
13 4 Pool maintenance: contrasting band on steps and benches No No No Contrasting color band on stairs 2” from side wall. Must be no more than 1” from side wall. .2521(b) Provide contrasting color band on leading edge of stair treads. *Will allow until 2023 permit to correct. Failure to correct will result in denial of permit for 2023
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled, not accessible in case of emergency. .2530(a) Lifesaving equipment should be conveniently located. *Immediate suspension item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed side gate that was not self closing and self latching. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. *permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter is at top and not giving accurate reading for flow. .2518(g) Keep flow meter operational. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed less than 3ft clearance in pump room. Chemicals stored in pump room. Chemicals on floor in pump room. No hose bib with backflow preventer. Pool built 1985 .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.