| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No total alkalinity, cyanuric acid, main drain, or pool maintenance records for last two months. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Both skimmers missing weirs. .2518(k) Provide functional weirs. - Intent to suspend item.
Skimmers full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder loose. .2521(b) Ladders shall be installed rigidly.
Escutcheon plate missing for handrail. .2521 Install handrails per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One patio gate propped open, corrected. Two other patio gates not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. - Corrected. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Underwater light not fully installed. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Bag of dry chemicals on pump room floor. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies.
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Piping no labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
No toilet paper in restrooms. .2526(l) Provide toilet paper and dispensers in restrooms.
Shower not functioning. .2526(h) Showers shall be provided in the proportion of one for each 200 persons at the time of maximum bather load. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose Bibb by shower does not have backflow preventor. .2512 (b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap or vacuum breaker (ASSE 1020 or 1013). |