5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
Observed pool log to be missing entry on days when the staff are off duty. Pool logs must be kept properly for every day the pool is open. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on the pool floor. Keep the pool clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 1 skimmer weir missing out of the 2 total skimmers. Replace the weir.
.2518(k) Replace missing weirs. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder step broken off and the ladder to be missing the rubber cap for the rail. Fix the ladder and replace the cap. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed missing vacuum line cap. I.S. Issued. Proper cap must be provided and must not extend more than 2 inches into the pool. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed throw rope to be not connected to the ring buoy. Rope was reattached and made to be 28 feet long exactly.
Observed body hook to be missing the bolts and nuts. Body hook was only held in with plastic spring fixture. Body hook was properly attached.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gates to have foot holds in the form of lattices attached to the gates. Remove the lattices. Gates and gate latches must function properly. They must full self-close and fully-self latch. Some gates were secured and could not be evaluated. I.S. Issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Observed some deck furniture to be closer than six feet from the water edge. Items were moved and the issue corrected. |