5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed previous records for last season and the past couple weeks where CA not checked. PIC stated he does not check CA often. Ensure TA and CA are checked weekly. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length that was less than 50ft. CDI CPO purchased new rope at proper length and attached to ring buoy. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed pool fence by upper deck with a height less than 40” and height between horizontals is 24”. Observed foothold outside of pool that makes easy access to enter pool outside of using gate.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed areas of fence with gaps of at most 7”. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(b) Provide sufficient lighting in pump room. Observed no lighting available in pump room.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bib in bathroom and on pool deck without backflow prevention device. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed no color or labels to identify pipes in pump room. |