Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRETREAT APTS AT MCALPINE CREEK, THE
Address6800 FISHERS FARM LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2023
Final Score @ Grade
36
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine registered below 1.0ppm
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8.pH registered too high at 8.2
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed a large amount of debris on pool’s surface.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Pool rope was observed above 50 ft, cut too size.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed greater than 4" under sections of fence near pump room and run off spaces. CDI - Pool operator filled these spaces in with rocks and other landscaping during inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate not self latching.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Some pool furniture was observed closer than 6 ft clearance.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed leak by pump area.