| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Log book water damaged from recent storm, has not yet been replaced. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor with leaves and sand. Leaves floating on water surface. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir installed backwards. .2518(k) Provide functional weirs.
Skimmers turned off in the pump room. .2518(k)(3) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow the skimmer is certified for under NSF 50. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing endcap. .2521 Install ladders per manufacturer instructions. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Vacuum cap damaged. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color bands on steps and benches faded. Will need to repaint prior to 2025 permit being issued. .2521(b) Provide at least 2" contrasting color band to edge of stair treads. .2516(b) Underwater benches shall be marked by a two inch contrasting color band. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Kings III phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automatic chemical controller unplugged. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not functioning in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Pump room full of chemicals and general storage items. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Bag of dry chemicals stored on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Pump and chemical storage rooms unlocked. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No Toilet paper on toilet paper dispensers in restrooms. .2526(l) Provide toilet paper and dispensers in restrooms.
No soap in the restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. |