Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameELAN AT MALLARD CREEK
Address2305 NEW ENGLAND ST
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/3/2023
Final Score @ Grade
28
General CommentsInspection conducted with CPO Tim Rankin. Updated CDP with CPO information. New Pentair Intelliflo XF 3HP pump installed. Electrical permit E4278648 passed inspection 11-4-2022. Emergency phone rings ~8 times. Recommend having Kings III reduce the number of rings. Some no diving markers on the pool deck cracked. Recommend replacing. NOTE - Main drains expire 9-28-2023. Will need to replace with new APSP-17 approved drain covers and submit updated PDSC form to our office prior to drain cover expiration. Pre-permit inspection did not pass. 8) 16) 24) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir not fully installed. .2518(k) Provide functional weirs. - Pre-permit item Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. Throw rope not attached and unravelling at the end. .2530(a) Provide USCG approved ring buoy with attached 42 foot throw rope at least 1/4 inch in diameter. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Large Spring on gate < 45” high, creating a foothold. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Window from the fitness center able to open all the way. .2528(a) Ground level windows shall not open greater than 4" on to pool deck. - Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No 2” flow meter installed on 4” return line. .2518(g) Install flow meter on return line per manufacturer instructions. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in men’s or women’s restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. No toilet paper in restrooms. .2526(l) Provide toilet paper and dispensers in restrooms. Men’s urinal does not flush. .2526(m) Keep restrooms and fixtures clean and in good repair.