NameMAA LOSO
Address4015 CRAFT ST
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/23/2023
Final Score @ Grade
26
General CommentsInspection conducted with Randolph Balzer. 30 day intent to suspend the permit issued for foot holds / horizontals less than 45” apart on pool deck balcony and furniture within 6’ of pool edge. Operator has 30 days to correct. Once corrected, call Hope McIntosh for a re-visit. At this time, Night Swimming is not approved.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water pH greater than 8.0. Corrected to 7.6.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(16) Mechanical cleaning equipment shall not be used while bathers are in the pool. Mechanical automated vacuum cleaning system in use in pool while pool in use. Operator removed.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Water level shall be maintained to assure skimmers are operable. Water level high such that skimmers are not operable. Reduce water level in pool to allow skimmers to function. Operator removed water from pool / lowered level to make skimmers operable.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Depth markers on pool walls not visible due to high water level. Reduce water level such that depth markers are clearly visible. Operator removed water from pool. Depth markers visible by end of inspection
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Observed furnishings pushed adjacent to barrier resulting in less than 45” between horizontal on balcony that leads directly to pool deck. Pool constructed 2021. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed bar-stool seating at grill area less than 6’ from edge of pool. *permit itme