Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANT AT STEELE CREEK
Address13212 WINTER HAZEL RD
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/28/2024
Final Score @ Grade
22
General CommentsConducted inspection with CPO Randy. Immediate suspension issued for emergency phone callback issue. Call or text EHS Devon Moeller when ready to reopen 7049981122.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Some Sundays in August missing. Ensure records are kept daily, even on weekends. No permit action.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder closest to clubhouse missing end cap. Replace. Loose handrail at entry. Keep tight and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Fence gate by pump room not self latching. Operator corrected. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence opening greater than 4” in multiple areas by pump room due to warping. Pool built in 2007. No permit action. Note: Clubhouse door is kept locked at all times due to door not self closing self latching.
22 6 Premises: emergency telephone provided No No No Emergency phone not receiving calls back, but dials out and connects to 911. .2530(f) Emergency phone shall remain operable. Immediate Suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter not operational. Operator corrected. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored in pump room. Move to designated chemical storage room.