NameAVANT AT STEELE CREEK
Address13212 WINTER HAZEL RD
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/7/2023
Final Score @ Grade
18
General CommentsInspection conducted with operator Randy. 30 day intent to suspend the permit issued due to missing record keeping, gate not latching upon closure and missing window limiter. Once all items are corrected call Hope McIntosh at 980-229-7549 or a re-visit will be conducted at 30 days. If all items are not corrected permit may be suspended.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No records documented since middle of August 2023. Records must be maintained daily. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder and handrail both loose.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope attached to ring buoy heavily frayed and detaching from rope. Operator corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Missing limiter on window opening from fitness room directly onto pool deck. *permit item .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Gate on seat side of pool not latching upon closure. *permit item .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Bent fence pickets with openings greater than 4”. Pool built 2007.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Pump and chemical rooms found to be unlocked and unattended at onset of inspection. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Storage around equipment in pump room. .2533(b) Provide sufficient lighting in pump room. Light not operational in pump room. .2534(6) Provide sufficient lighting in chemical storage room. Light not operational in chemical room