Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANT AT STEELE CREEK
Address13212 WINTER HAZEL RD
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/15/2023
Final Score @ Grade
14
General CommentsInspection conducted with operator Randy Medrano. Note: re-plastering of pool surface is in planning with contractor. Prior to beginning work, provide documentation to the department with regard to scope of job along with materials/colors to be used. EHS emailed plan review document to operator.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Establishment has changed form of daily record keeping. New form does not have main drain checks included - no main drain checks documented for January. PIC added main drain check to forms. All other record items in compliance.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2514 - slip resistant surfacing of pool bottom with damaged areas. Re-plastering of pool is in planning.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence opening greater than 4” in multiple areas. Pool built in 2007. 2528(a) Provide no openings in fence and/or gate greater than 4"x4".
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No ventilation or lighting in chemical storage. No 3’ clearance around piping in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.