Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANT AT STEELE CREEK
Address13212 WINTER HAZEL RD
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/22/2022
Final Score @ Grade
24
General CommentsIssued local permit sticker. No Night Swimming. CPO updated to Randy Medrano. “A” Open for Business. Repair pool tile on wall prior to 2023 season.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No One pool wall tile missing by entry stairs. Replace and keep in good repair. Repair prior to 2023 for permit. Lack of severity does not warrant permit action at this time.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker missing “FT” at 41/2 ft. .2523(c) Depth markers shall include the word "feet" or symbol "ft". Operator added “FT” and corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Loose handrail at entry. Keep tight and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence opening greater than 4” in multiple areas. Pool built in 2007. 2528(a) Provide no openings in fence and/or gate greater than 4"x4". Gate on side not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted to self-close, self-latch. Corrected.
22 6 Premises: emergency telephone provided No No No Incorrect dialing instructions at phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator corrected to read “Dial 911” instead of automatically dials.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No ventilation or lighting in chemical storage. Chemicals stored in pump room. No 3’ clearance around piping in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(6) Provide sufficient lighting in chemical storage room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels in men’s restroom. Provide hand drying in men’s restroom.