Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTOWERVIEW BALLANTYNE - SPA
Address13230 BALLANTYNE CORPORATE PL
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 3/19/2026
Final Score @ Grade
14
General CommentsIssued 30 Day Intent to Suspend (ITS) for inlet fittings and records. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. “W” ITS status Expiring/Expired Covers - Requires replacement 2026. 12/15/2026. AUTOFILL SENSOR IS TIED INTO BOTTOM OF BENCH AND APPEARS AS “RETURN FITTING”.FEATURE PUMP IS TIED INTO JET PUMP TIMER SWITCH. FEATURE WILL NOT RUN WITHOUT JET PUMP. AQUASTAR FILT/FEAT MAIN DRAINS EXPIRE 2026/LAWSON JET MAIN DRAINS EXPIRE 12/15/2031 Update and send approval of PDSC PRIOR to expiration to avoid permit action. Website is eh.mecknc.gov/pools spa ID 550203 Submit to pdsc@mecknc.gov Visit with Rob Bailey, Teddy Chapple and Tejon Gerald Updated CPO to Theodore Chapple

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH over 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.Operator adjusted to 7.8. Corrected. Note: Spa staying voluntarily closed until full turnover and stable water quality is met.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing temperature and weekly alkalinity testing. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *permit item
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Multiple jet fittings missing at time of inspection. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *permit item