Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTOWERVIEW BALLANTYNE - SPA
Address13230 BALLANTYNE CORPORATE PL
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 8/21/2023
Final Score @ Grade
26
General CommentsImmediate Suspension issued for emergency phone. Spa must remain closed with signage posted until suspension is lifted by health department. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. At return visit, other permit items to check includes recordkeeping, weirs, door and flow meter. “E” Immediate suspension

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekend checks, maintenance and weekly cyanuric acid at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. *Permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weirs installed backwards. .2518(k) Replace missing weirs. *Permit item
14 4 Pool maintenance: spa timer working properly No No No Timer exceeding 15 minute run time. .2537(b) Spa timer shall not exceed 15 minutes without manual resetting. *permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door not latching into spa. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item
22 6 Premises: emergency telephone provided No No No Emergency phone not working at time of inspection. .2530(f) Emergency phone shall remain operable. *Immediate suspension item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. *permit item