5
|
0
|
Procedures for responding to vomiting & diarrheal events |
Yes |
No
|
No |
2-501.11 A food establishment shall have written procedures for employees to follow when responding to vomiting or diarrheal events. -Pf For more information please visit: http://meck.co/FoodSafety. Observed no written procedure for responding to vomiting or diarrheal events.. CDI. provided PIC with one. |
|
10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
5-205.11 (A),(B) Maintain access to handsinks. Handsinks may only be used for handwashing.-Pf. Observed employee carrying water from hand sink. CDI. Made a correction. |
|
40
|
0
|
Personal cleanliness |
Yes |
No
|
No |
2-402.11 Use head coverings, beard guards and clothing to restrain body hair from contacting exposed food, equipment, and utensils. Observed employee working without hair cover. CDI. Employee wore one.
2-303.11 Remove jewelry on hands and arms while preparing food. A plain ring, such as a wedding band, is allowed. Observed employee working in the kitchen with the watch one. |
|
41
|
0
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses. Observed wet wiping cloths stored directly on the table. CDI. PIC removed. |
|
49
|
0.50
|
Non-food contact surfaces clean |
Yes |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris. 4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed build up out of the RI cooler and ice machine. Needs to be cleaned. |
|
51
|
1
|
Plumbing installed; proper backflow devices |
Yes |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed drain leaks on the floor. Needs to be repaired. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed water leaks on the floor. Needs to be cleaned. |