Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOLLINS APARTMENTS, THE
Address1001 STONECLIFF RD
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/11/2023
Final Score @ Grade
42
General CommentsInspection conducted with operator Brian. Immediate suspension of permit issued due to improper water chemistry - chlorine and pH out of compliance, body hook removed from pole, emergency phone signage no longer posted. Once all items corrected, call Hope McIntosh at 980-229-7549 for a return visit. Pool closed and signs posted during inspection. Pool must remain closed with signs posted until suspension is lifted. At that time, a 30 day intent to suspend the permit may be issued for missing record keeping and improper wording on rules sign,

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine found to be 0.0 ppm. Automatic chemcial feed system not operable. *immediate suspension item
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water pH at 8.0. Chemical feed system not operable. *immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. No records available for review since May 2023. *permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers observed with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Body hood detached from 12’ pole. Pole now in use for cleaning brushes. *immediate suspension item
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." Signage posted does not have this required wording but instead reads “Children shall not use the pool without an adult in attendance”. Exact wording is required. Previously alternate rules sign posted in addition to this sign but has now been removed. *permit item
22 6 Premises: emergency telephone provided No No No .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Emergency Phone signage damaged/detached and laying upside down on concrete. Phone is not readily visible from all seating areas. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Signage with address and phone number detached and laying on pool deck. Not posted at emergency phone area. *immediate suspension items
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bags of dry chemicals stored on floor in chemical storage room. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Doors to both pump room and chemcial room kept unlocked and accessible.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Missing most labeling on pipework and valves in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Water temperature in mens restroom exceeds 110f.