23
|
1.50
|
Proper date marking & disposition |
Yes |
No
|
No |
3-501.17 Date mark/label all TCS foods that are ready-to-eat once opened or prepared and held more than 24hrs. -Pf Observed no date mark on seasoned salmon in prep top cooler. Larger container in cooler had a date mar of 9/9. CDI: Salmon dated for prep date of 9/9.
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed shrimp wonton mix and impossible gyoza mix cooling in walk in cooler in a deep pan with a lid. CDI: Product split into multiple pans and placed in ice bath. Product cooled at proper rate.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed left door of small plates reach in cooler gasket is damaged. Observed steamer door gasket damaged. |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed food build up on gasket of steamer. Ensure more frequent cleaning. Observed ice build up on interior of reach in freezer in back kitchen. REPEAT VIOLATION |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed stained ceiling tiles in cooking area. REPEAT VIOLATION Previous violation corrected. |