3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator added bicarb and corrected to 7.2. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records not being kept on weekends. Weekly tests and maintenance missing.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope too short at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator replaced with new rope 50’. Corrected. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lighting fixture not secured to wall. .2524(c) Lighting fixtures shall not present a hazard to the public. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor with water. .2533(d) Pump room floor shall be kept dry and free of standing water. |