Inspection Date 9/15/2026
Final Score @ Grade
14
General CommentsLifted suspension and conducted inspection. Issued permit. No Night Swimming “A” Open for Business Permit Restriction: Flow meter must remain operable. Flow required at 82 gpm to 100 gpm to meet turnover and flow restriction of the main drain covers. Suction Hazard. Flow greater than 103 gpm exceeds the return pipe sizing. Updated CPO to James Elliott Inspection with Anthony McNeill, James Elliott and Jamie Broome

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not being kept at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected. Discussed test kit usage.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing rubber end caps. .2521 Install ladders per manufacturer instructions. Operator placed end caps on ladder and corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope too long. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator replaced rope to new buoy and cut to 41’. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals on floor in pump room. No chemical storage. No 3’ clearance. Observed pump room doors in poor repair (door lock can be easily bypassed). Repair so doors can be locked and secured. 2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Pool built 1989 .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. Operator moved off floor. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.