5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records not being kept at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected.
Discussed test kit usage. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing rubber end caps.
.2521 Install ladders per manufacturer instructions. Operator placed end caps on ladder and corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope too long.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator replaced rope to new buoy and cut to 41’. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals on floor in pump room. No chemical storage. No 3’ clearance. Observed pump room doors in poor repair (door lock can be easily bypassed). Repair so doors can be locked and secured. 2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Pool built 1989
.2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. Operator moved off floor.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.