5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed main drain safety checks not being recorded daily. Observed no record keeping done on weekends. Intent to suspend permit issued. Correct within 30 days. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder with missing rubber end caps. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 missing return fitting. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading onto pool deck with audible alarms disabled. CDI- alarms were activated.
Observed 1 door where lockers are located not self-closing. Intent to suspend permit issued. Correct within 30 days. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool lounge furniture within 6 feet of pool. CDI- relocated. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Lock in poor repair. Locked door able to be easily bypassed. Repair.
.2533(d) Pump room floor shall be kept dry and free of standing water. Water on pump room floor due to leak in pump. |