8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs.
Observed two missing weirs out of the six total.
Replace missing weirs. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment should be conspicuously and conveniently located.
Observed rope of the ring buoy haphazardly tied around the USCG approved tube.
EHS corrected during inspection, taking several minutes to untie.
Keep rope of ring buoy stored in a manner to easily access during emergency situations. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational.
Flow meter stuck at time of inspection. CPO unable to fix during inspection.
INTENT TO SUSPEND ITEM. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Observed non-weatherproof bag of sodium bicarb stored directly on the floor inside the chemical storage room.
Ensure all non-weatherproof bags of chemicals are stored off of the floor to prevent contamination. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
.2526(l) Provide toilet paper and dispensers in restrooms.
Observed no soap, toilet paper, or paper towels available at the unisex restroom.
Obtain above mentioned items. |