Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRINGLE SQUARE APARTMENTS
Address15157 OLLIE DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/22/2025
Final Score @ Grade
24
General CommentsConducted inspection with CPO and property manager. Intent to suspend issued for records and gate. Call EHS Devon when corrected 7049981122. Items must be corrected within 30 days or pool permit may be suspended. DRAIN COVERS EXPIRE 5/26/2026 Const. Date: 5/26/2021 Rope Length: 50' No night swimming. PERMIT RESTRICTION: 1) SALT IS NOT APPROVED AS PRIMARY CHLORINATION. 2) BATTERY BACK-UP MUST REMAIN OPERABLE ON GATES.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water 6.8. Operator corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No TA or CA checks and no main drain checks. Half of September missing for pH and chlorine. Weekends missing for July and August. Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. One weir missing by handicap chair. Second weir missing by pool ladder. 3 out of 5 weirs still intact. No permit action.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conveniently located. Observed one ring buoy with rope heavily tangled and not usable. Operator corrected. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Gate closest to clubhouse not self latching. Intent to suspend item.