Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRINGLE SQUARE APARTMENTS
Address15157 OLLIE DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/12/2021
Final Score @ Grade
16
General CommentsConstruction final passed. Permit issued for no night swimming. As unannounced follow-up inspection will be completed within 30 days. Ensure chlorine at least 1.0 ppm through chlorinator and pH at 7.2 to 7.8. Maintain daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for total alkalinity and cyanuric acid. Note: Temporary signage approved. Incorrect address on signage. New sign is on order. Note: Wood added to barrier at pump room where fence ties into building to decrease gap to <4". Temporary repair. Permit Restriction 1. Pool is not approved for salt as primary chlorination. 2. Battery back-up must remain operable for barrier. Filtration – Hayward HCP30201, 2 hp pump with (2) Aquastar 12MFxxx drain covers. EQ lines plugged in skimmer. Feature – Hayward SP3207EE, ¾ hp pump with (2) Aquastar 12MFxxx drain covers. Max Depth – 5 ft. Pool Width – 33 ft. Rope Length – 50 ft.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Screw loose in main drain. Tightened during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >4" between post and picket at tie into building near pump room. Added wood to decrease opening as temporary repair. <4" at time of inspection. Ledge near front leasing office tie in near fitness center provides foothold. Added angle piece to eliminate foothold on building. Rock drainage areas with >2" from ground to bottom of barrier. Piled rocks during inspection. Must maintain 2" or less at all times.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Drain valve on chlorinator leaking. Added plug to valve during inspection to repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet in pump room around chlorinator due to leak at drain valve. Keep pump room floor dry.