Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Operator added chemical to raise; however, automated feeder is not calibrated and was adding acid upon entry to the pump room. Ensure pH maintained at 7.2 to 7.8. Feeder shall be calibrated to reopen. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Cyanruic acid not recorded weekly. Record weekly. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
New drain covers installed. Old were expiring in May. No VGB paperwork submitted. Submit PDSC form for approval to katie.rudisill@mecknc.gov. PDSC form shall be approved prior to scheduling a return visit to reopen the pool. Immediate Suspension issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir stuck forward on 4 ft. skimmer. Keep operable so skimmer functions per NSF standard. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Some rust build on step handrails into pool. Keep fixtures in good repair. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Grab rope on ring buoy degrading. Ring buoy rope at 33 ft. and degrading. Provide new USCG approved ring buoy with 36 ft. rope. Immediate Suspension issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool lounge chairs less 3 ft. from pool edge. Maintain 6 ft. clearance around the pool in all locations. Operator moved during the inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automated feeder not calibrated. Automated feeder shall be calibrated to read what pool chemistry is. Reading 7.4 and pool at 7.0. Automated feeder shall detect flow when pump turned off. Be able to demonstrate. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leak at heater pipe. Keep dry.
Dry chemicals stored on room outside of pump room/chemical storage room. Store pool chemicals in approved chemical storage room. |