5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Log book not easily accessible. Provide log book records showing daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for total alkalinity and cyanuric acid. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some algae on grout on tile on pool floor. Keep pool free of algae and pool floor clean.
Waterline tile with build-up. Keep clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with debris. Emptied during the inspection. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Pool light hanging into pool and not secure. Imminent Hazard. Secure pool light to wall. Immediate Suspension issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Grout line beginning to degrade in line between coping and deck at handicap lift. Monitor and repair if worsens. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorine feeder not operable. Facility having to manually feed chlorine and acid into the pool. The pool shall be chlorinated through an NSF approved chlorinator. Manual feed is not permitted. Immediate Suspension issued.
Feeder shall detect flow and turn off when no flow is detected. Be able to demonstrate. |