General CommentsRick Culver present during the inspection. Intent to Suspends issued for the following: .2528 - repair both doors to self-close, self-latch .2522/.2537 - eliminate cushions to ensure at least 6 ft. clearance around pool; repair deck drain .2535 - repair cya feeder to ensure automated and detects flow from pump or eliminate A return visit will be made in 30 days to verify completion of ITS items. Facility given until January 1 to repair pool plaster and pool lights.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some tiles missing from pool walls. Repair. Pool floor with damaged plaster. Operator stated they are in under warranty and will be getting fixed in October. Given until January 1 to repair pool floor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some build-up/algae under skimmer lids at sun shelf area. Ensure skimmers kept clean.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Rust around light fixtures and one light fixture secured to wall by zip tie. Fittings shall be kept in good repair. Repair/replace as needed. All metal in pool shall be stainless steel. Ensure light fixtures are flush to wall. Will be done at same time as the pool plaster. Requires repair prior to January 1.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Screw missing from body hook. Repeat item. Screw provided during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Main door not self-closing, self-latching. Door into kitchen affixed back. Door not opening from outside. Fob system not operational. Repair both doors to self-close, self-latch. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Cushions directly next to pool around at least 1/2 of swimming pool. Maintain 6 ft. clearance around the pool in all locations. Intent to Suspend issued. Missing piece on drain near emergency phone. Repair to eliminate openings >1/2". Intent to Suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Cyanuric acid feeder not automated. Is not tied into pump and does not detect flow. If wanting to utilize acid feeder, must be tied into pump to ensure feeder turns off with no flow from pump. Intent to Suspend issued.