Inspection Date 8/17/2021
Final Score @ Grade
16
General CommentsOnsite visit to pool for return construction. Construction final passed. Permit issued for no night swimming. An unannounced follow-up inspection will be conducted by EHS within 30 days of permit issuance. Kenneth Smith and Nate Roberts present during the inspection. Note: Small leak at pool pump at piping from pump to filter. Repair leak prior to follow-up inspection. Note: Long wall mirror in restroom not covered with backing tape. Removed during the inspection. Do not install until safety backing tape applied to entire mirror. Note: TCO on pump room excluding the use of the heater. Heater not approved until mechanical permit M3834303 is finaled. Note: Restroom floor approved through plan review without slope. Floor does not appear to slope to drain in all locations. Note: Pool rules signage temporary. Permanent signage ordered. Pentair Whisperflo WFET-4, 1 hp pump with (2) Paramount SDX2 drain covers. EQ lines plugged in skimmers. Max Depth – 4 ft.; Pool Width – 24 ft.; Rope Length – 36 ft. Permit Restrictions 1. Portable vacuum required. Pool built without vacuum. 2. No glassware to be served to patrons in the pool deck area. Barrier is building. Barrier must remain around swimming pool to separate pool deck and restaurant. Signage required at entry points to prohibit glass. Doors shall remain self-closing, self-latching. 3. Turf area is outside of required deck space but may become slip hazard if not properly drained. If occurs, repair may be required. 4. Heater not approved for use until mechanical permit is finaled. 5. Limited deck space. Required 6 ft. clearance around pool. 6. Long mirror in men's restroom not approved until backing tape applied.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level high due to large quantity of rain. Lower water level so that skimmers are operable.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture less than 6 ft. from pool edge. Corrected during the inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at pipe fitting from pump to filtration. Repair leak. Does not appear to affect pool circulation. Equipment still within warranty. Follow-up with pool contractor and repair leak. Repair prior to return inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet due to small leak. Keep floor dry. Light burnt out in chemical storage room. Replaced during the inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Long mirror in men's restroom not covered with backing tape. Removed during inspection. Do not replace in restroom until backing tape applied to entire mirror.