Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBROADSTONE AYRSLEY
Address2200 SILVER CRESCENT DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/22/2026
Final Score @ Grade
16
General CommentsPerformed inspection with CPO new to the property Jonathan Roundtree and EHS Hope M. Pool remains in good standing and on A status. Note: EHS Devon observed many decking offsets approaching 1/2”. Repair deck before offsets become a trip hazard. CPO stated decking maintenance is planned. Note: Small chip at corner of 1/2 FT depth marker. Lettering intact. EHS recommends replacing tile. Pool not heated. Const. Date: 7/1/2021 Rope Length: 40'6 Night Swim?: N Note: SALT IS NOT APPROVED FOR PRIMARY CHLORINATION.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide weekly recordings for cyanuric acid and total alkalinity. Two weeks of CA and TA checks missing. All other records intact and complete. Ensure consistent weekly TA and CA readings. No permit action.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Some staining/discoloration/algae of pool floor, under loungers, and by steps. Operators scrubbed. No permit action.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. No diving marker at far end of the pool broken at corner. Operator repaired and glued down broken piece. EHS recommends replacing tile before next inspection. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Back gate not self closing. Operator repaired. No permit action.