Inspection Date 8/1/2022
Final Score @ Grade
24
General CommentsImmediate Suspension issued for chlorine. Once corrected, contact Katie to re-open the pool. Pool Closed signs posted during the inspection. Light bulbs on some patios around pool deck. Bulbs shall be shatterproof or moved into interior of the patio. No glass on pool deck. Pool is not approved for night swimming. If seeking night swimming, an additional site visit will be required to verify sufficient lighting is present. Signs indicate pool operates until 10:00. Adjust signage for dawn to dusk. Omelquis Martinez present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No chlorine in pool. Maintain chlorine at least 1.0 ppm through chlorinator. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid and total alkalinity not recorded weekly. Cyanuric acid over 100 ppm. ITS item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 3 out of 5 skimmers with plug on suction side of skimmer. Skimmers shall be plugged on line that is capped on underside. No suction in skimmers that are plugged. ITS item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate not self-closing, self-latching. Repair right side gate (interior looking) to self-close, self-latch. ITS item. Could not access rooms 167, 172, and 182 to verify doors as self-closing, self-latching. ITS item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Flow meter not operable on chlorinator. Repair. ITS item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Door to pump room not locking. Repair so that door locks.