Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTAYBRIDGE SUITES CHARLOTTE AIRPORT
Address6017 TYVOLA GLEN CIR
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/30/2022
Final Score @ Grade
22
General CommentsIssued Immediate Suspension for water quality. Pool MUST REMAIN CLOSED with signage posted until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Other permit items to verify at return visit includes records (complete, accurate, all fields required) and flow meter operational. Inspection with James Childress “E” Immediate Suspension

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing, not complete and not accurate. No records for main drain, temperature or chlorine. No total alkalinity readings. PH recording 3-6, 5-10, no information on maintenance or chemicals. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope not attached to buoy at time of inspection. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Operator attached rope and corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operating at time of inspection. .2518(g) Keep flow meter operational. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals in equipment room. Items within 3' of equipment piping at time of inspection. One bag of dry chemicals on floor. LIght out in chemical storage. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(6) Provide sufficient lighting in chemical storage room.