2
|
1.50
|
Management and food employee knowledge, and conditional employee; responsibilities and reporting. |
Yes |
No
|
No |
2-103.11(M) Ensure food employees are informed of their responsibility to report required symptoms, illnesses and exposure. -PF Observed no employee health policy in use at time of inspection. CDI provided EHP Poster in Mandarin. |
|
18
|
1.50
|
Proper cooling time and temperatures |
No |
No
|
No |
3-501.14(A) Quickly cool cooked foods within 2 hours from 135F to 70F; and within a total of 6 hours from 135F to 41F. -P Observed breaded chicken cooled from last night at greater than 41 degrees. Observed chicken wings and breaded chicken cooling at insufficient rate to meet cooling parameters. CDI Products from last night discarded and products from today were placed on sheet pans and moved to freezer and proper cooling achieved. |
|
20
|
1.50
|
Proper cold holding temperatures |
No |
No
|
Yes |
3-501.16 (A)(2) and (B) Potentially Hazardous Food (Time/Temperature Control for Safety Food), Hot and Cold Holding - P Observed items in walk in cooler at greater than 41 degrees included raw beef and chicken received less than 4 hours prior to inspection. CDI moved to alternate refrigeration and technician dispatched to check on walk in cooler. |
|
31
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf
Observed chicken wings and breaded chicken cooling covered and in too dense of a layer in walk in cooler . CDI moved to sheet pan and took to freezer where proper cooling was achieved. |
|
45
|
1
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed gasket on reach in cooler and freezer in need of replacement. |
|
53
|
0.50
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed caulk at three compartment sink in need of replacement. |