Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVION POINT
Address2327 APEX LANDING WY
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/28/2021
Final Score @ Grade
14
General CommentsOnsite visit to pool with Brock Melton for return construction. All items from construction corrected except items noted in inspection. Corrected during the site visit. Construction final passed. Joshua Jett present for operating permit. Operating permit issued for no night swimming. A follow-up inspection will be made by the Health Department within 2 weeks. Temporary meshing added to barrier in two locations. If replaced, must meet code requirements. Permit Restriction 1) Polymeric sand on pavers must remain in good repair. Item to Correct prior to follow-up visit. 1) Meshing on gate/barrier >1/2"x1/2". Repair meshing to 1/2"x1/2" or eliminate openings >1/2" within 18" of push bar on all gates/fencing Note – (2) drains in middle are for Filtration drains. (2) outside drains are for feature pump. Filtration – Pentair Whisperflo WFE-6, 1.5 hp pump with (2) Aquastar 914xxx drain covers. EQ lines plugged in skimmer. Feature – Pentair Whisperflo WFE-3, ¾ hp pump with (2) Aquastar 914xxx drain covers. Pool Width – 31 ft. Rope Length – 46 ft. Max Depth 5 ft..

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log book not maintained. Pool was not open to the public at time of inspection. Ensure daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for total alkalinity and cyanuric acid. Log book onsite during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Meshing on gate/barrier >1/2"x1/2". Repair meshing to 1/2"x1/2" or eliminate openings >1/2" within 18" of push bar on all gates/fencing prior to follow-up inspection. >4" between post and picket near emergency phone. Corrected with meshing to eliminate opening. <45" between Duke box and horizontal on barrier and at tie into main building from electrical to horizontal. Meshing added to eliminate horizontal to maintain 45". >1/2" between post and gate on all three gates. Metal added during inspection.
22 6 Premises: emergency telephone provided No No No Phone number not posted at emergency phone. Corrected during the inspection. Recommend providing permanent signage. Written in with sharpie.