Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCANDLEWOOD SUITES
Address7926 FOREST PINE DRIVE
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/20/2021
Final Score @ Grade
32
General CommentsNOTE: Pre-permit inspection conducted 5/19/2021 from 2:00 p.m. to 3:30 p.m. Establishment changed to seasonal permit from annual and software will not allow correct date entry of inspection. Motor observed was 1.25 THP, PDSC and files indicated 3/4 HP, pump is correct, but motor may cause issues with size. Manager stated motor was changed in 2018 with pump. Advised that work should be done according to code and by a licensed electrician. Did not observe imminent hazard at time of visit. Changed to "A" Open for Business. Inspection with: Chris Moss and Janet Shaver No signature due to COVID Pool not heated

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.1 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator added chemicals and corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records for pool at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Operator took readings and recorded. Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Entrance handrail loose at time of inspection. Keep tightened. .2521 Install ladders per manufacturer instructions. Operator tightened and corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Two buoys with rope on deck. One rope too long. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected to 24'. Body hook bolt missing from pole at time of inspection, small piece of straight plastic in hook, not secure. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Operator added bolt and secured hook to pole. Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone off the hook at time of inspection. .2530(f) Emergency phone shall remain operable. Operator reconnected and corrected. *Note: When emergency phone is called back, phone rings to front desk, hotel staff cannot locate where emergency call was made from (pool). Advised correcting phone line to display where emergency call was made from on property in the event of emergency.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck at time of inspection. .2518(g) Keep flow meter operational. Operator adjusted and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Water on floor in pump room. No ventilation in equipment room. No 3' clearance around piping/equipment. Pool built '01. Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Keep pump room floor free of standing water. Provide forced or cross ventilation. Provide 3' clearance around equipment.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water in restrooms over 110 degrees F. .2526(i) Water in restrooms shall not exceed 110 F. Unable to verify type of mirrors in restrooms. .2526(k) Provide shatterproof mirrors. If mirrors are glass, a backing can be placed on them to make shatterproof.