| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
1
|
0
|
PIC present, Demonstration - Certification by accredited program, and performs duties |
Yes |
No
|
No |
2-102.12 PIC shall demonstrate knowledge by being a certified food protection manager.
Facility is within 210 days of permitting and points are not assessed today. |
|
2
|
1.50
|
Management and food employee knowledge, and conditional employee; responsibilities and reporting. |
Yes |
No
|
No |
2-103.11(M) Ensure food employees are informed of their responsibility to report required symptoms, illnesses and exposure. -PF
PIC was not familiar with employee health policy requirements. CDI - gave PIC copy of EHP document. |
|
8
|
1
|
Handwashing sinks, supplied and accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf
Observed paper towels were inaccessible at hand sink. CDI- PIC adjusted towel dispenser.
5-205.11 Handsinks may only be used for handwashing.-Pf observed utensil stored in hand sink. CDI removed utensil. |
|
14
|
1.50
|
Food-contact surfaces: cleaned and sanitized |
Yes |
No
|
No |
4-602.11 Clean the equipment and utensils used with TCS foods as required to avoid contamination. -P
Observed utensils used with TCS foods to have been in use for > 4 hours. Unit did not have water to wash, rinse, and sanitize utensils.
CDI- MFU voluntarily closed today and IS issued. |
|
20
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
Yes |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P
Observed multiple TCS foods in refrigeration > 41F. See temperature chart.
CDI- TCS food items discarded by PIC. MFU voluntarily closed and IS issued.
Verification required within 10 days. |
|
26
|
1
|
Toxic substances properly identified, stored, and used |
Yes |
No
|
No |
7-102.11 Label working containers of toxic materials such as cleaners and sanitizers.-Pf
Observed unlabeled spray bottle containing bleach.CDI by discard.
7-204.11 Provide sanitizer at correct concentrations, diluting as required.-P
Observed spray bottle of bleach that PIC stated was sanitizer testing > 200ppm chlorine. CDI by discard. |
|
38
|
0
|
Personal cleanliness |
No |
No
|
No |
2-402.11 Use head coverings, beard guards and clothing to restrain body hair from contacting exposed food, equipment, and utensils.
PIC was observed without a hair restraint. |
|
43
|
0
|
Single-use and single-service articles; properly stored and used |
No |
No
|
No |
4-903.11(A) Store single-use and single-service articles to prevent contamination and at least 6 inches off the floor.
Observed single service items stored on the floor. |
|
45
|
0
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair.
Observed flip top cooler with ambient temperature of 55F in top of unit. Possible issues with generator and capacity to power the unit. |
|
48
|
0
|
Hot and cold water available; adequate pressure |
No |
No
|
Yes |
5-103.11(B) Provide sufficient hot water to meet the peak hot water demands.-Pf
Observed unit in operation without hot water. Possible issues with generator and power supply.
CDI- IS issued. MFU will remain closed until inspection of the unit can be completed.
Verification required within 10 days. |