Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameELLIS, THE - HIGH RISE
Address512 N COLLEGE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/23/2024
Final Score @ Grade
44
General CommentsNote: Large wasp nest on pool deck. Eliminate wasps to eliminate hazard. Immediate Suspension issued for the following: .2535 - maintain chlorine at least 1.0 ppm through chlorinator and pool pH at 7.2 to 7.8. .2530 - provide USCG approved ring buoy with 25 ft. 6 in. rope. .2530 - phone not operable - could not verify callback, address or phone number. Luis Rosado present during the inspection. Pool Closed signs posted during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Pool chlorine at 0 ppm. No tablets for chlorinator. Salt system was off. Pool is not approved for salt as primary chlorination. Maintain chlorine at least 1.0 ppm through chlorinator. Immediate Suspension issued.
3 6 Water quality: pool water pH No No No Pool pH at 8.0. Immediate Suspension issued. Maintain at 7.2 to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No CYA and TA not recorded weekly. Record weekly. Some days missing from daily record keeping. Ensure chlorine, pH and main drain checks recorded daily.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Grab rope degraded on ring buoy. Ring buoy rope too short. Provide at 25'6". Provide new USCG approved ring buoy with rope. Immediate Suspension issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Glass in gates not secured so openings between glass and post >1/2". Provide permanent repair to glass so it does not move.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to coping near bench. Repair damage. Opening >1/2".
22 6 Premises: emergency telephone provided No No No Phone not operable. Would not connect to 911. Could not verify address, phone number, signage or callback. Immediate Suspension issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Flow meter on stick feeder chlorinator leaking. Replace chlorinator/repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet in pump room due to leak at flow meter. Keep floor dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Soap dispensers out of soap in women's restroom. Provide soap at all sinks.