Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameELLIS, THE - HIGH RISE
Address512 N COLLEGE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/2/2021
Final Score @ Grade
4
General CommentsOnsite visit to pool with contractor Danny Poole, HOAR construction. Construction final passed. Permit issued for no night swimming. An unannounced follow-up inspection will be conducted by Environmental Health within 30 days of permit issuance. If seeking night swimming, a return visit will be required before dawn or after dusk to verify sufficient lighting present on the pool deck. Holds released in system. 1. Missing grout near emergency phone. Chipping out. Re-grout. Could not do at time of inspection due to rain. Ensure corrected by follow-up inspection. 2. Barrier did not meet code upon arrival. All items corrected during the site visit. Key fob system had shorted and was not operational. Gates set at fail-safe close. Verified. Rocks added below barrier at tie into wall. Ensure 2" or less under barrier. Recommend permanent repair by adding metal across the bottom. Note – Steel plates have been painted. Temporary and will be replaced with pavers. Offset not >1/2”. Approved as is. Note - Facility provided pool rules signage with incorrect wording. Added generic white and blue pool rules sign during inspection. If removed, facility signage must read "Adults should not swim alone." and "Children should not use the swimming pool without adult supervision." Permit Restriction 1. Pool not approved for salt as primary chlorination. If wanting to switch to salt, provide specs on chlorine production lbs/day of cell. (2) Salt cells currently installed. Filtration – Pentair Whisperflo WFE-6, 1.5 hp pump with (2) Aquastar 914xxx drain covers. EQ lines plugged in skimmer. Fire Suppression Pump – Patterson 5x4x12SSC, 200 hp pump. Tied to (4) Aquastar 914xxx drain covers. Pool Width – 17 ft. Rope Length – 25 ½ ft. Max Depth – 3 ½ ft.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Small amount of grout missing near emergency phone. Could not repair at time of inspection due to rain. Correct by follow-up inspection.