Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTHRIVE AT UNIVERSITY CITY
Address310 CHARGER CT
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/13/2021
Final Score @ Grade
26
General CommentsInspection conducted with Micholas Cox. Due to COVID-19 precautions, inspection was not signed by the operator. - Pool closed signs not provided. .2530(e) Pool closed signs shall be provided and shall be posted at bather entrances whenever an operational permit is suspended. - Pre-permit item. Pool primarily chlorinated with salt generated. Salt levels low. Recommend having salt meter onsite to measure salt levels. Pre-permit inspection did not pass. Correct the following prior to scheduling return inspection. 2) 3) 16) 18) 28) Provide at least 4 pool closed signs (4 entrances) A $100 reinspection fee will need to be paid prior to scheduling a reinspection. This can be done by calling our main office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Pre-permit item.
3 6 Water quality: pool water pH No No No pH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One piece of plexiglas missing by back gate. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Pre-permit item.
18 4 Premises: lifeguards present or warning signs posted No No No Safety signage with 3/4" lower case lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item. Safety signage with 3/4" lower case lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Pre-permit item.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower sign not provided. .2526(a) Post a shower sign visible upon entrance to the pool.