Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMERCURY NODA APARTMENTS
Address3310 N DAVIDSON ST
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/23/2025
Final Score @ Grade
12
General CommentsMain drain covers expire 2/27/2030 Equalizer line covers expire 2/3/2026 Equalizer lines must be replaced with covers appropriate to the system flow rate and the PDSC forms submitted to the Health Department and approved prior to this date. Alternately the equalizer lines could be disabled by plugging the lines at the wall, removing the water from the line, and plugging the line in the skimmer also. If the lines are disabled, these steps must all be taken and PDSC forms reflecting the change must be submitted. PERMIT RESTRICTION: 4” MAXIMUM HEIGHT FOR PLANTERS IN PLANTERS LOCATED NEXT TO POOL.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Missing 1 weir out of 4 total skimmer weirs. No permit action taken.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture to be too close to the water edge. I.T.S. Issued. Deadline is 10/23/2025. Failure to correct this issue by the deadline will result in closure of the pool.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter stuck. Repair the flow meter. Pump system does not have flow restriction. No permit action taken.