2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. Observed chlorine to be higher than 10.0 and to bleach the indicator. Correct the chlorine level. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be higher than 8.4. Correct the pH. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Vacuum line cover must have a cap that needs a tool to open. Cap is missing. A new cap with spring loaded self closing cover must be provided and it must also require a tool to open. I.T.S.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed the barrier wall of a unit to be missing the screen in the rain drain gap. Replace the screen. Opening is greater than 4 inches. |